Ilerfred
Ilerfred

Ilerfred

Cooling and CA

Ilerfred Installs Refrigeration System for a Logistics Warehouse at Mercabarna

Industrial Leridana del Frío S.L., ILERFRED, has been dedicated to the design, execution, and maintenance of refrigeration and controlled atmosphere installations since 1986. On this occasion, they have carried out the installation of a refrigeration system for a logistics warehouse at Mercabarna, intended for the preservation of fruits and vegetables. The refrigeration system uses glycol water and is cooled using an efficient and natural refrigerant, propane (R-290). Technical Data Refrigeration power installed on the technical rooftop: 344 kW for the production of glycol water at temperatures of -8ºC/-4ºC. The installation comprises two propane chillers with a refrigeration power of 172 kW each. The defrost system for the installation uses hot glycol at a fluid temperature of +35/+30 °C. The hot glycol is obtained through a heat recovery unit installed in the same chiller plants, ensuring high energy efficiency. Type of Installation Design and execution of a glycol water system, cooled using the natural refrigerant propane and pumped to the preservation chambers. Services Refrigeration for a total of six preservation chambers

5
13 November, 2023

Industrial Leridana del Frío S.L., ILERFRED, has been dedicated to the design, execution, and maintenance of refrigeration and controlled atmosphere installations since 1986. On this occasion, they have carried out the installation of a refrigeration system for a logistics warehouse at Mercabarna, intended for the storage of fruits and vegetables. The refrigeration system uses glycol water and is cooled using an efficient and natural refrigerant, propane (R-290). Technical DataRefrigeration power installed on the technical rooftop: 344 kW for the production of glycol water at temperatures of -8ºC/-4ºC. The installation comprises two propane chillers with a refrigeration power of 172 kW each. The defrost system for the installation uses hot glycol at a fluid temperature of +35/+30 °C. The hot glycol is obtained through a heat recovery unit installed in the same chiller plants, ensuring high energy efficiency. Type of InstallationDesign and execution of a glycol water system, cooled using the natural refrigerant propane and pumped to the preservation chambers. ServicesRefrigeration for a total of six storage chambers

Plan de Recuperación, Transformación y Resiliencia Financiado por la Unión Europea